Other questions

1. How to proceed the learning circle for ES200

a.    A. Move the panel to half open position
b.    Set program switch to “close”
c.    On power, should close slowly
d.    Start learning cycle when panels is close
e.    Start learning cycle, press “SERVICE(The Red button), release the button when door leaves moving open slowly, learning cycle proceed. Meanwhile, The LED on module blink, Door leaves move to open positon slowly, LED 8 on Module blink twice, learning cycle complete.
f.       Menu items must be detected P = 0.. b = 1.. r. — L – A – According to optional combinations of modifications.

2. How to proceed the learning circle for ES200E

a.    Move the panel to half open position
b.    Set program switch to “close”
c.    On power, should close slowly
d.    Start learning cycle when panels is close
e.    Start learning cycle, press “SERVICE”(The Red button), release the button when door leaves moving open slowly, learning cycle proceed. Meanwhile, The LED on module blink, Door leaves move to open positon slowly, LED 8 on Module blink twice, learning cycle complete.
f.    Menu items must be detected P = 0.. b = 1.. r. — L – A – According to optional combinations of modifications.

 

3. My door opens when it is raining. What can I do?  
 
      There are various possibilities: a) If the door remains open without any fault signal, it may be that the photoelectric cells/light barriers are being interrupted by water droplets => Clean and dry the light barrier lenses with a soft cloth. It may also be that the external radar motion detector is being activated by the falling raindrops (detected as a moving object) => Have the motion detector adjusted by our service department. b) If the door is opened and a fault signal is being emitted => The number of causes is numerous, so please inform our service department. 

4. The red LED on my control board lights up. What can and may I do myself?  
 
      The red LED shows the presence of a fault. The fault can often be eliminated by switching the system on and off several times at the program switch (see the relevant operating instructions for the door in question). If the fault signal is then immediately repeated, consult the troubleshooting section of the operating instructions in order to rectify the problem. If you are unsuccessful, please inform our service department. 

5.  What are the maximum panel height and opening width?  
 

      The panel height and opening width are mainly restricted by the maximum permissible panel weights. These in turn depend on the operator being used. In addition, however, it will be necessary to remain within certain height/width ratios that have been specified in order to ensure the smooth and low-wear running behaviour of the door system. You can consult our sales advisers who will be glad to assist.

6. How can I modify the speed of my automatic door?  
 
      The adjustment possibilities depend on the operator used. ES200E or EC100 operators can be adjusted directly at the control unit or DEBIS. ES200 operators can only be adjusted using a special programming unit, the CAESAR PDA, used by CAESAR service technicians. 

 
7. Is the maintenance of sliding doors mandatory and if so, how often? (all operators)  
 
      A clear distinction has to be made here between "Maintenance" and "Inspection". Inspections are specified in the standards and are mandatory – they either have to be carried out once a year. In its operating instructions, CAESAR recommends that doors be serviced twice a year.

 
8. Where do I route the connection leads?  
 
The connection leads are generally fed in from the side. The connection side depends on the operator type and is illustrated in the relevant technical brochure or cable diagram. 

Leave a Comment